is there a rule of thumb to errecting posts & panel sign

<<

User avatar

Premium Member
Premium Member

Posts: 8338

Joined: Sun Mar 31, 2002 1:00 am





Post Fri Apr 26, 2002 1:01 am

is there a rule of thumb to errecting posts & panel sign

Question ?
Is there a formula for setting posts ?

I.E. Length of post 4mtr size of panel 1 mtr x 1 mtr depth of hole = ?

I have put up quite a few small panels and never really thought about it before, but I am quoting a job with a larger panel size and thought this must be important.
<<

User avatar

*****
*****

Posts: 27234

Joined: Wed Dec 12, 2001 1:00 am

Country: United Kingdom (uk)




Post Fri Apr 26, 2002 1:14 am

quick answer mate. hense the time.
there are regulations if its road signs your doing.

if its just a run of the mill for a factory sign. then a good guide is if you walk under the sign does your head hit the sign> :lol:

if so you need a bigger pole.. :lol:


remember the larger the pole the deeper it goes. 5mtr pole is about 35" in the ground min so take that of the hight of the pole then the depth of the signs off the pole and see whats left.
<<

User avatar

4 Star Contributor

Posts: 387

Joined: Sat Nov 24, 2001 1:00 am





Post Fri Apr 26, 2002 8:49 am

as a rule of thumb we usually aim for a third of the total height of the sign to go under ground ie, 3m high, 1m underground, hole approx 1000x500x500 will suffice which is 250,000 cubic centimeters of concrete which is fair enough to stand up to the gales we have in this country. ......

when you start getting bigger a change in the foundations is required, usually using cages and a concrete raft etc...........

but it also depends on ground condition, concrete mix etc

BIG subject to get into !!!! :lol:
<<

5 Star Contributor

Posts: 1196

Joined: Wed Nov 21, 2001 1:00 am





Post Fri Apr 26, 2002 9:28 am

When I first got into all this we used to do quite a lot of panel and post stuff.

As Paul says allow about 1 third underground two-thirds above.

One thing I've discovered is that, in most cases, where you are fixing into undisturbed ground there is nothing quite so hard as the ground itself, specially a foot or so down. So, we normally use a deep small hole (say a 10" diam hole for a 3" diam post) which uses less concrete and then 'tamp' it down really hard. It's then not so much a case of whether the wind will dislodge the concrete footing but whether it can physically prise the posts from the ground itself!

Once, when we had a flat panel sign (6 or 8 foot square if I recall) on two legs in a particularly exposed location, very windy most of the time, Spandex actually supplied the sign set but advised that their calculations suggested there was a small possibility that the type of legs we had ordered might 'fold' in extreme gale conditions.

I happened to mention this to a mate, who was a builder, and he said "...no problem, once you've fitted the sign, remove the post caps and, using a plastic funnel, fill the posts with fine sand and nothing will ever bend that post again.." we did - he was right - it's still there eleven years later!

always thought it was a clever tip and that I'd pass it on...
<<

User avatar

4 Star Contributor

Posts: 387

Joined: Sat Nov 24, 2001 1:00 am





Post Sat Apr 27, 2002 9:56 am

thats a good tip.......spandex should have supplied you the bloody sand as well for the prices they charge....lol :o
<<

User avatar

Premium Member
Premium Member

Posts: 8338

Joined: Sun Mar 31, 2002 1:00 am





Post Mon Apr 29, 2002 2:08 pm

Thanks for all the help guys, now for the $64,000 question.

The panel is 2mtr square what diamater posts should I use and at what length?
<<

User avatar

4 Star Contributor

Posts: 387

Joined: Sat Nov 24, 2001 1:00 am





Post Mon Apr 29, 2002 5:02 pm

err dunno mate, i only work here

Return to General Sign Topics



Who is online

Registered users:
No registered users

 

About
Contact
Board Rules
Membership
Terms & Conditions

 

Signapp - iPhone & iPad
Signapp - Android
Vehicle Wrap Training
Vinyl Application Training
Vehicle Wrap Accreditation
UK Sign Group
Site Membership
Advertising
Videos
ISA-UK

 

 

Who is Online

In total there are 14 users online ::
1 registered, 0 hidden and 13 guests
[based on past 5 minutes]

Most users ever online was
370 on Tue Aug 28, 2018 5:02 pm

Registered users:
No registered users

Copyright © 2000 - 2019 Robert Lambie